Crack Repair of Upper Protection Plate

Industry Type
Steel

Product Group
Lotherme

OUR SOLUTION

Product
Lotherme-705

Size (mm)
4.00

Current (amps)
95-125

Quantity (Kgs)
0.4

Power Source
Rectifier

Polarity
Straight

ANALYSIS

Equipment Name
Battery (Coke Oven)

Component Name
Upper Protection Plate

Type Of Problem
Crack

Problem Due To
Load

Previous Solution
Used C.I electrodes of L&T Make

Base Metal
Cast Iron

JOB PICTURES

Job Sketch With Dimension

Job Sketch With Dimension

Job Sketch With Dimension

Job Sketch With Dimension

Procedure

1. Clean the crack area &identified the cracks.

2. Gouging &grinding operation are carried out to remove the cracks completely.

3. Pre-heating is not required as the job is already at continuous heat zone. Welding job to be carried out IN SITU.

4. Welding is carried out using Lotherme 705