Ductile Iron Pipe Joining For Pressur Test

Industry Type
Steel

Product Group
Mech

OUR SOLUTION

Product
Lotherme-703, Lotherme-705

Size (mm)
3.15

Current (amps)
100, 105

Quantity (Kgs)
14, 12

Process
Rectifier

Polarity
Straight

Preheat (°C)
60

ANALYSIS

Equipment Name
Pipe

Component Name
Pipes

Type Of Problem
Broken

Problem Due To
Joining For Pressur Testing

Previous Solution
XYRON 2240

Base Metal
Ductile Iron

Dimensions (mm)
6000 x 10 x 200

JOB PICTURES

Ductile Iron Pipe Joining With Lotherme 703,705.

Ductile Iron Pipe Joining With Lotherme 703,705.

Hydralic Pressur Test Found Ok

Hydralic Pressur Test Found Ok

Procedure

1. 4 Pipes edges made the grove by grinding machine.

2. Each pipe joints made tocka weld apposit sides

3. Pre heated the pipes up to 60 dig.

4. Cast iron welding prociser made the grove joinings 50mm opposite sides and complited the total pipe welding using our lotherme 705 dia 3.15mm and one more pipe with lotherme 703 dia 3.15mm.

5. They tested the both the pipes hydralic pressur test found satisfactory.

Further Reading on Case Studies

WELDING REBUILDING OF RING ROLLING CO-AXIAL ROLL

Read Case Study