Bearing Housing worn-out Covering of copper coupings

Industry Type
Sugar

Product Group
Lotherme

Our solution

Product
L-352

Size (mm)
4

Current (AMPs)
160

Qty. (Kgs)
4

Product
L-510N

Size (mm)
4

Current (AMPs)
160

Qty. (Kgs)
4

ANALYSIS

COMPONENT NAME
Bearing Housing

TYPE OF PROBLEM
Worn out

PROBLEM DUE TO
Heavy Pressure

PREVIOUS SOLUTION
L&T s 660NH & XHD 2222

BASE METAL
CARBON STEEL

COMP. WEIGHT
50kgs

DIM ENSIONS (mm) L x T x W
1000 x 800 x 800

Procedure


  1. GOUGE 

  2. Heat the job by 150 degrees

  3. First Layer by Lotherme-352

  4. Take the crack root

  5. Final Layer By Lotherme-510N

  6. Machining the final layer

Further Reading on Case Studies

WELDING REBUILDING OF RING ROLLING CO-AXIAL ROLL

Read Case Study
Contact Us