Hardfacing Of Static Coller

Industry Type
Sugar

Product Group
Electrode

OUR SOLUTION

Product
Lotherme -605

Size (mm)
4.00

Current (amps)
120

Quantity (Kgs)
10

Process
SMAW

Power Source
Rectifier

Polarity
+VE

ANALYSIS

Equipment Name
Roller Side Static Coller

Component Name
Static Coller

Type Of Problem
Frictional Wear

Problem Due To
Metal To Metal Wear And Compressive Load

Previous Solution
Rebuild With E124(Ador) And No Hardfacing

Base Metal
SS Liner Fitted Over Mild Steel

Comp. Weight (Kgs)
300 Kg

Dimensions (Mm)
20

JOB PICTURES

Job Sketch With Dimension

Job Sketch With Dimension

Procedure

1. Remove the fatigue metal.

2. Clean the surface from grease and dust

3. Weld the wear out area with loth-605, 4.00 mm, is used to resist the metal to metal wear.

4. Grind the surface upto level of surface.

Further Reading on Case Studies

WELDING REBUILDING OF RING ROLLING CO-AXIAL ROLL

Read Case Study
Contact Us